1 ¾ for Commercial Attack……Why Not?

By: Battalion Chief Shannon Stone

City of Fort Walton Beach Fire Dept. Fla.

Now that I have your attention, take a moment to read this and provide feedback.

Couple of disclaimers; I’m not a writer so please be kind and I’m not advocating the use of 1 ¾ for commercial fires, but rather reaching out to those who are knowledgeable in this area and asking for feedback.

Recently during flow testing apparatus in my department, an engine company approached me and asked me a question. “What do you think about flowing and operating a 1 ¾ line flowing 260 GPM in place of  2 ½ line flowing 260 GPM?” You can imagine my response….”No way, we don’t use 1 ¾ for high flow GPM and we certainly wouldn’t use it to replace a 2 ½ line on a commercial job.” As you can imagine this started a debate which led to much testing and this article for County Fire Tactics. I will make this as brief as possible.

 

All flows were flow tested with a flow meter at the intake, nozzle reactions calculated multiple times, and tested advancing lines in full PPE simulating fatigue factors (not live fire). An “apples for apples” comparison was done with two identical tests. Both evolutions were performed with a four man company, the same firefighters in the same positions every evolution. They advanced the hose lines into a drill tower room 1, flowing to the left, shut down moved to the right and flowed, advance to the next room and flowed, advanced to the 2nd floor and flowed, advanced to the 3rd floor and flowed. Each time the nozzle was opened it was operated at full capacity for 30-60 seconds. Here are the details:

 

Evolution #1 – 2 ½ inch Ponn Conquest hose, 200 ft, solid bore nozzle with 1 1/8 tip

  • Engine pressure of 80 PSI equaling 265 GPM
  • As everyone knows, 2 ½ hose advancement is labor intensive and even with four well trained firefighters, the fatigue factor was still a concern
  • Firefighters had to work extra hard to manage the kinks in the line. They were never successful in removing all the kinks and this was performed in a drill tower where the obstacles are far less than an actual building.
  • Proper techniques were used by all especially by the nozzle man and back up firefighter
  • General assessment of the evolution is that it was very tiring and all firefighters were winded, but of course they said what all firefighters say “But we got it!”

IMAG2617 IMAG2614

Kink management was difficult at best with the 2 ½ advancement. The hose team was never successful in managing all the kinks in the line. Keep in mind there were numerous pivot points for this advancement.

Evolutions #2 – 1 ¾ inch Ponn Conquest hose, 200 ft, solid bore nozzle with 1 1/8 tip

 

  • Engine pressure of 140 PSI equaling 260 GPM
  • Half the weight allowed the firefighters to move the line very easily, much quicker, and more efficient than the 2 ½.
  • There was only 1 kink during the entire evolution which was easily corrected by a firefighter.
  • Proper techniques were used by all especially the nozzle man and back up firefighter. This is a 1 ¾ line but absolutely has to be operated and staffed like a 2 ½ line when flowing 260 GPM.
  • General assessment of the evolution is it was much easier to advance and the firefighters said they felt way less fatigued. They described it as no different than advancing any other 1 ¾ attack line. The nozzle man also stated that due to the smaller diameter of the 1 ¾ hose, he felt it was easier to hold and control the nozzle position.
Bleeding the line checking the stream preparing to advance the 1 ¾.

Bleeding the line checking the stream preparing to advance the 1 ¾.

Although hard to tell by looking at pictures but the kink factor was decreased significantly. Notice the nice stiff bends in the hose in comparison to the pictures of the 2 ½ hose.

Although hard to tell by looking at pictures but the kink factor was decreased significantly. Notice the nice stiff bends in the hose in comparison to the pictures of the 2 ½ hose.

IMAG2637

Wrapping the wall, stairwell, and rooms are essential with minimal staffed fire departments. The 1 ¾ worked very well due to the high pump pressure. It never kinked when utilizing these advancement methods. However, 2 ½ would kink immediately rendering this technique less effective resulting in numerous kinks.

Wrapping the wall, stairwell, and rooms are essential with minimal staffed fire departments. The 1 ¾ worked very well due to the high pump pressure. It never kinked when utilizing these advancement methods. However, 2 ½ would kink immediately rendering this technique less effective resulting in numerous kinks.

IMAG2636

Here are additional facts:

 

  • Nozzle reaction for both the 1 ¾ and 2 ½ are virtually identical since the GPM and diameter of the nozzle are the same.
  • Kink flow testing revealed that on average a kink in the 2 ½ hose would result in the flow decreasing from 265 GPM to 240 GPM.
  • Kink flow testing revealed that on average a kink in the 1 ¾ hose would result in the flow decreasing from 260 GPM to 210 GPM. The significant decrease is obviously due to the amount of water flowing through a smaller diameter hose.
  • 2 ½ hose was guaranteed to kink, 4 firefighters could not manage all the kinks resulting in a decrease average flow of GPM.
  • 1 ¾ hose was extremely difficult to kink due to the high pump pressure. Only one kink that was corrected easily and quickly. The average GPM was around 250-260.
  • Low friction loss hose was used (Ponn Conquest). Anyone who is a student of the fire service understands the actual diameter of this hose is slightly larger that standard hose (or slightly larger than what the manufactures actually advertises it as); however, manageability of the low friction loss hose vs the standard hose is identical.
  • High pump pressure had no negative bearing on advancement or operation of hose
  • The nozzle man has the same range of motion with the 1 ¾ line as the 2 ½ line
  • Reach, penetration of the fire stream of each was identical

 

Advantages of the 1 ¾ option

 

  • Literally ½ weight in comparison to 2 ½
  • Nozzle controllability was the same if not better with the 1 ¾
  • Line advances easier, faster, and more efficient
  • Fatigue factor was much less that 2 ½
  • Average GPM was greater than the 2 ½ (kink factor)

 

Disadvantages and limitations to the 1 ¾ high flow set up

  • It is likely that anything over 200 ft of 1 ¾ set up will not work due to high friction loss factors.
  • This should not be considered in high rise fires due to high friction loss factors. This would include most if not all standpipe operations.
  • If the 1 ¾ nozzle is operated too far out in front of the nozzle man, a serious “whipping or snapping” action of nozzle can occur. This is easily controlled by proper nozzle control and operation.

Summary

 

A quick special thanks to my guys that insisted I take a look at this. Fort Walton Beach Fire Department Engine Company 7– Acting Captain Justin Westmoreland, Engineer Mark Birchett, and Firefighter Brandon Waterhouse.

 

The testing we performed was much more comprehensive than what this article shows, but in an effort to make it brief and a quick read I stuck the meat and potatoes of the issue. In no way am I implying that we in the fire service move away from use of 2 ½ hose for large fire or commercial fire attack. However, the numbers and facts speak volumes that I believe are worthy of evaluating. If you think about it, this is no different from the evolution of 1 inch hose, to 1 ½ hose, to 1 ¾ hose, to low friction loss hose which now allows us to flow larger volumes of water under manageable conditions. I do buy into the concept of limiting your nozzle reaction and insuring you have a manageable line so the nozzle is ALWAYS operated properly during significant fire conditions-nozzle all the way open. This is why this 1 ¾ set up absolutely has to be operated as if it is a 2 ½ line insuring adequate staffing to insure correct deployment and operation.

 

So I beg the question….what are we missing here? What’s your thoughts and/or experiences with high flow, smaller diameter hose? Should this be a viable option for large fire attack?

Tactical Safety- Video Killed the Fire Star

DirtyDozen

Tactical Safety for Firefighters

Video Killed The Fire Star

By Ray McCormack

Video of fire scenes show us as we are. They are not complementary. They are real. While we all feel better because we would never look that bad, are you sure? Some will aways be poor performers and some will just have a bad day with the video rolling.

What we often see is poor task skills incorporated within a poorly structured attack plan. While some individuals stand out due to various errors, they are often operating within a broken system. So, two problems emerge: firefighter errors and scene disorganization. The bigger of these two errors is improper scene management- a total lack of SOP or SOGs, just Helter Skelter!

The task issue of forcing a door or stretching a line incorrectly can hopefully be overcome by someone who paid more attention to those lessons at the academy. Firefighters all learn skills in training school and hopefully rework the memory muscle at house drills; however, when we witness task errors throughout, we are witnessing dysfunction. Fireground dysfunctionality is not easily solved on scene because the problem goes deep. The problem is the fire goes out and no injuries are encountered and we collectively pat ourselves on the back and nothing improves. For many, there is no need for improvement if these two benchmarks are reached.

Beyond skill drills which make up the foundation of firefighter training, we need to also incorporate fire operations protocol . We need to revisit the fire academy as groups and work on our approach to fires in people’s homes. We need to practice directing the actions of firefighters. We need to have our firefighters not just in bunker gear, but truly ready to work on air. our leader needs to understand that good fireground management starts long before arrival on scene. Remember if you want to look good look practice your act.

In Ray’s class, “Engine Company Errors – The Dirty Dozen”, a lack of SOPs is cited as error number one.

Keep Fire in Your Life

Tactical Safety: No Two Fires Are The Same

tacsafe

Tactical Safety for Firefighters

No Two Fires Are The Same

By Ray McCormack

Have you heard the phrase, “No Two Fires Are The Same”? It is not true!

There are plenty of fires that are the same. They may not be identical , but they are very much alike. This statement, like others, has taken on a life of its own and, if strictly adhered to and believed, can impact negatively on fireground operations.

Unless your response area contains completely custom one-of-a-kind homes, then your department has experienced some fires that were the same.

While the postal couriers motto talks about rain, snow, sleet and gloom of night never impacting the swift completion of their rounds, the same is not true of the fireground. Time of day, weather, etc. impact us, but the fire’s location within the dwelling type doesn’t vary. A kitchen fire in a ranch in a neighborhood of predominantly ranch style houses is just that, a repeatable similar fire. A second floor rear bedroom fire in a condo among hundreds just like it in a development is the same fire.

The effect on operational safety comes when we firmly believe the statement that no two fires are the same and therefore do not take the time to evaluate our response area to discover the occupancies that are similar and develop SOGs for such building fires.

What happens next is that a lack of SOGs impacts efficient operations and the dispatching of tactics which then must be ordered instead of being intuitive. When everyone is awaiting the most remedial of orders, we will experience delays and delays equal fire growth in this business. Never had a fire that was the same as another? Think again!

Keep Fire in Your Life

Tactical Safety: Taking Sides

trans2

Tactical Safety for FirefightersTaking Sides

By Ray McCormack

There are only two sides to a fire building: the inside and the outside.There are those who want us to stay outside for a variety of reasons. There are those who see us as incapable of making good decisions regarding entry. There are those who fail to truly understand our capabilities employing interior fire attack.

Fire, smoke, occupancy, construction, time of day, troop strength, timing, and water issues are all valid reasons to stay outside and many can be misread or exaggerated keeping you outside. We are all hazard – “check”. We are firefighters – “check”, but wait. There seems to be some difficulty in pulling the interior extinguishment pin for some. If your scales tend to tip toward the outside and you know that it isn’t really necessary, then why would you continue?

Do you feel that the inside of the fire building is too dangerous for your firefighters to operate in? What happens when the exterior option is off the table? What are you going to do then? Are your tactics going to tame it? Have you sat down and figured out what your extinguishment is going to look like?

Are you operating under an assumption that our capabilities don’t include interior success? What is missing from your extinguishment platform that you have trouble handling a bread and butter fire. It can’t be equipment because we all have the necessary hoses and nozzles. Do you believe there is no such thing as a bread and butter fire in the modern age? If so, that is a bad assumption.

To arrive at a burning home and base your operations on exaggerated conditions places most firefighters in a state of paralysis, and that must be fixed so that your people know they can be successful with either option.

Finding the tactics that you need to get extinguishment done is not an unknown, but it may take practice for some. Start by not feeding it unnecessarily and its bite will be less powerful. We need to get our people inside to find the savable and the injured. I know that I want someone coming for me if I’m inside, don’t you?

Keep Fire in Your Life

Direct Water Application “The Transitional Attack”

Direct Water Application Escambia

Why does this not push FIRE? Why is it ok that FIREFIGHTERS are inside? Is this an aggressive attack?

Crew is inside making the push.

This is the Back Up Line Assisting the Interior Crew make the push on FOUR ROOMS OF FIRE.

Firefighters are inside pulling and Flowing while they open the roof. Do you think the above picture is showing an aggressive TACTIC?

Transitional Attack Taking Place in a Large City! It worked. Great call by the Battalion Chief...

Fire Out! They HIT it HARD with Engine mounted Deck Gun while opening up and making access for interior attack lines. Transitional : passage from one state, place, stage, or subject to another : CHANGE!!! Photo by: Pat Grace

Multiple Attack Lines Off Tank Water

When do you stretch Multiple Attack Lines off the First Due Engine on arrival? What is the consumption or cost of charging those lines off tank water? How many Firefighters are needed to operate these lines? Do your firefighters understand when to SHUT down, even if the fire has not been knocked down? We need to THINK in terms of Gallons Per Second when operating off TANK WATER!!

Water Supply— When do we secure a hydrant?

Image

When do we need to pump LDH?

When do you need to pump LDH? This Company is Moving Big Water.

Water Supply

Do you pre-connect NST/Storz to hose or leave in hydrant bag? Top Three Photos By: Phil Cohen “Camden NJ”

Does your company/driver understand how to pump the four-way valve?

When do we need to pump LDH? Do you use some type of fourway valve?

First Due Stretched Attack line. Second Due gave a three inch feeder "water supply" and supported Fire Attack. Third Due secured hydrant. Just a thought for some Suburban/County Fire Tactics. This allowed for a rapid and successful knock down with timely searches and ventilation.

Securing a hydrant is so high on so many Fire Ground Commanders’ check list; they sometimes fail to really evaluate the Fire Flow needs. They have it ingrained to get a hydrant. First, I would like to say most Working Fires are controlled with Tank Water. And most, if not all LODDs have nothing to do with a lack of on-scene water. I am a big advocate of using water to need more. So, why do we put in our tactics text books that the second due secures water? Or better yet place it in our SOGs? I will tell you why! Because some time in the past; we ran out of water trying to make a knock on a FIRE. Then the following day a MEMORANDUM came out “FIRST DUE WILL SECURE A HYDRANT”. I guess the thinking is that this would guarantee success at all fires.

Do not miss-read this post. I would love to have a hydrant in front of every structure that was on fire. This is not the case. So we must train on decision making with conditions at hand. When dealing with a normal size house and your first two engines carry Suburban Booster Tanks/Suburban Manning, evaluate your capabilities. Time Your Tank and account for Tactical Priorities!

Well, what if the first on-scene Engine “crew of three with 752.5 gallons of water on board” has a one room fire on the second floor of a small private dwelling with possible entrapment? Now how important is it for second due to secure a hydrant while only two firefighters stretch an attack line and try and advance in and upstairs with a return staircase. The FLASHOVER will happen before you even get a supply line in place and even then the line will not take back what has already occurred. Let’s evaluate the needs here. More firefighters to assist getting a line upstairs to extinguish with Gallons per Second/PRE-VENT FLASHOVER or have second due secure a hydrant so when the house goes fully involved because the crew of three could not reach the one room fire they will have a secured water supply. Then will the static supply lay of 500’ really supply what you need? Please don’t put the cart before the horse. Just because the First Arriving Engine secures a hydrant does not guarantee success. But, if you’re going to secure a hydrant then why not do it 100%. You think, what is a 100%? That would be when the hydrant is fully tapped and a Pump pulling the water and then pushing it. There can be over 500 GPM difference at only 300’ of LDH. Remember friction loss does exist in LDH. Seven pounds per 100’ using 5” at a 1000 GPM and 20 pounds per 100’ of 4” at 1000 GPM flow. The other problem is the residual water available when not fully tapping the PLUG. We have found nearly 25% more water available when fully tapping.

Success is only a possibility when Firefighters FIRST and Fire Officers Second, understand Fire Ground Tactics. Firefighters are the ones stretching and applying the water. They are the ones at the hydrant by themselves.  Fire cannot be extinguished with Strategy alone. Fires cannot be extinguished without Tactics. So make sure your Firefighters can perform their required Tactics and then confirm your Officer knows when and why to call for specific types Tactics to be performed. Just simply stating to always catch a hydrant first will not guarantee success.

When looking at your water supply capabilities look at your hydrant bag first. Does it carry two ball valves to full tap plug? Do you have a 2.5” NST to 5” storz for the plugs that do not have a steamer and/or it is unable to be opened? Does your hydrant bag has the steamer to storz connection in the BAG or pre-connected to the hose in bed? I HIGHLY RECOMMEND do not pre-connect!! Having it pre-connected does not SAVE TIME. It only limits your capabilities. When your bag has everything but the steamer to storz, it’s incomplete. What if you do a reverse supply and the steamer to storz is left at the scene and the Hydrant firefighter now has everything but the BIG CONNECTION? What if you need to hook up to a 2.5” port? Now you must remove before connecting.  What if you decide to hook-up a four way valve? Then, there are the ones that will not swivel freely and your LDH gets turns in it. If it was not pre-connected, you just spin it on and then click in the storz. LAST and MOST important!!! Connecting storz with locks on them is a ONE PERSON JOB. Disconnecting storz with locks will most likely be a TWO PERSON JOB. Do you carry a pipe wrench for hydrants that are old and your hydrant wrench cannot get a grip on valve? Escambia had a Fire where the hydrant wrench would not work because it would not close enough to grip.

So if you really need hydrant water than make the most of it. The Big Fires need Big Water. If you’re dealing with a house fire and people are possibly trapped evaluate your priorities and manpower available. It is awesome if you have Engines and Trucks arriving at the same time as to always allow the Second Due Engine to secure a hydrant. The problem is most of the Fire Service does not have this available.

So at your next Fire ask yourself if it is more manpower or more water you need first. If it is water you need; make the most of your supply.

Why would you not apply a hose clamp everytime?

Why would you not apply a hose clamp? This allows the hydrant firefighter to charge hydrant and advance to scene.

Are you think about a split lay? What if the NST to Storz was pre-connected?

Do you consider split lays? How does this assist fast water? How does this assist with Big Water?

Do you take advantage of short sections of LDH?

Do you take advantage of short sections of LDH? Do you just pull another 100' off the rear to create more kinks and apparatus blockage?

The ability to allow more apparatus into the scene. The ability to control water supply at the scene.

Escambia Engine 4 Hydrant Bag. What do you carry and where?

Direct Water Application “The Transitional Attack”

Image

Direct Water Application Escambia

Why does this not push FIRE? Why is it ok that FIREFIGHTERS are inside? Is this an aggressive attack?

Crew is inside making the push.

This is the Back Up Line Assisting the Interior Crew make the push on FOUR ROOMS OF FIRE.

Firefighters are inside pulling and Flowing while they open the roof. Do you think the above picture is showing an aggressive TACTIC?

Transitional Attack Taking Place in a Large City! It worked. Great call by the Battalion Chief...

Fire Out! They HIT it HARD with Engine mounted Deck Gun while opening up and making access for interior attack lines. Transitional : passage from one state, place, stage, or subject to another : CHANGE!!! Photo by: Pat Grace