Laying the pipeline with one apparatus. Lay in and then out. Use the fourway on the forward and pump back the reverse.
Laying the pipeline with one apparatus. Lay in and then out. Use the fourway on the forward and pump back the reverse.
Comments are closed.
Subscribe now to keep reading and get access to the full archive.

This is for getting a supply from two hydrants with one apparatus. The first hydrant is hooked up with the fourway and later arriving can pump. The second hydrant on the reverse can be hooked directly to the apparatus and pumped. We have been able to acheive an additional 1000+GPM off the same main with this type of supply.