1 ¾ for Commercial Attack……Why Not?

By: Battalion Chief Shannon Stone

City of Fort Walton Beach Fire Dept. Fla.

Now that I have your attention, take a moment to read this and provide feedback.

Couple of disclaimers; I’m not a writer so please be kind and I’m not advocating the use of 1 ¾ for commercial fires, but rather reaching out to those who are knowledgeable in this area and asking for feedback.

Recently during flow testing apparatus in my department, an engine company approached me and asked me a question. “What do you think about flowing and operating a 1 ¾ line flowing 260 GPM in place of  2 ½ line flowing 260 GPM?” You can imagine my response….”No way, we don’t use 1 ¾ for high flow GPM and we certainly wouldn’t use it to replace a 2 ½ line on a commercial job.” As you can imagine this started a debate which led to much testing and this article for County Fire Tactics. I will make this as brief as possible.

 

All flows were flow tested with a flow meter at the intake, nozzle reactions calculated multiple times, and tested advancing lines in full PPE simulating fatigue factors (not live fire). An “apples for apples” comparison was done with two identical tests. Both evolutions were performed with a four man company, the same firefighters in the same positions every evolution. They advanced the hose lines into a drill tower room 1, flowing to the left, shut down moved to the right and flowed, advance to the next room and flowed, advanced to the 2nd floor and flowed, advanced to the 3rd floor and flowed. Each time the nozzle was opened it was operated at full capacity for 30-60 seconds. Here are the details:

 

Evolution #1 – 2 ½ inch Ponn Conquest hose, 200 ft, solid bore nozzle with 1 1/8 tip

IMAG2617

Kink management was difficult at best with the 2 ½ advancement. The hose team was never successful in managing all the kinks in the line. Keep in mind there were numerous pivot points for this advancement.

Evolutions #2 – 1 ¾ inch Ponn Conquest hose, 200 ft, solid bore nozzle with 1 1/8 tip

 

Bleeding the line checking the stream preparing to advance the 1 ¾.

Although hard to tell by looking at pictures but the kink factor was decreased significantly. Notice the nice stiff bends in the hose in comparison to the pictures of the 2 ½ hose.

Wrapping the wall, stairwell, and rooms are essential with minimal staffed fire departments. The 1 ¾ worked very well due to the high pump pressure. It never kinked when utilizing these advancement methods. However, 2 ½ would kink immediately rendering this technique less effective resulting in numerous kinks.

Here are additional facts:

 

 

Advantages of the 1 ¾ option

 

 

Disadvantages and limitations to the 1 ¾ high flow set up

Summary

 

A quick special thanks to my guys that insisted I take a look at this. Fort Walton Beach Fire Department Engine Company 7– Acting Captain Justin Westmoreland, Engineer Mark Birchett, and Firefighter Brandon Waterhouse.

 

The testing we performed was much more comprehensive than what this article shows, but in an effort to make it brief and a quick read I stuck the meat and potatoes of the issue. In no way am I implying that we in the fire service move away from use of 2 ½ hose for large fire or commercial fire attack. However, the numbers and facts speak volumes that I believe are worthy of evaluating. If you think about it, this is no different from the evolution of 1 inch hose, to 1 ½ hose, to 1 ¾ hose, to low friction loss hose which now allows us to flow larger volumes of water under manageable conditions. I do buy into the concept of limiting your nozzle reaction and insuring you have a manageable line so the nozzle is ALWAYS operated properly during significant fire conditions-nozzle all the way open. This is why this 1 ¾ set up absolutely has to be operated as if it is a 2 ½ line insuring adequate staffing to insure correct deployment and operation.

 

So I beg the question….what are we missing here? What’s your thoughts and/or experiences with high flow, smaller diameter hose? Should this be a viable option for large fire attack?